Visual Features in Stereo-Electroencephalography to Predict Surgical Outcome: A Multicenter Study

Author(s): Abdallah C; Thomas J; Aron O; Avigdor T; Jaber K; Doležalová I; Mansilla D; Nevalainen P; Parikh P; Singh J; Beniczky S; Kahane P; Minotti L; Chabardes S; Colnat-Coulbois S; Maillard L; Hall J; Dubeau F; Gotman J; Grova C; Frauscher B;

Objective: Epilepsy surgery needs predictive features that are easily implemented in clinical practice. Previous studies are limited by small sample sizes, lack of external validation, and complex computational approaches. We aimed to identify and validate visually stereo-electroencephalography ( ...

Article GUID: 40519108


Spectral and network investigation reveals distinct power and connectivity patterns between phasic and tonic REM sleep

Author(s): Avigdor T; Peter-Derex L; Ho A; Schiller K; Wang Y; Abdallah C; Delaire E; Jaber K; Travnicek V; Grova C; Frauscher B;

Although rapid eye movement (REM) sleep is often thought of as a singular state, it consists of two substates, phasic and tonic REM, defined by the presence (respectively absence) of bursts of rapid eye movements. These two substates have distinct EEG signatures and functional properties. However ...

Article GUID: 40394955


A spatial perturbation framework to validate implantation of the epileptogenic zone

Author(s): Jaber K; Avigdor T; Mansilla D; Ho A; Thomas J; Abdallah C; Chabardes S; Hall J; Minotti L; Kahane P; Grova C; Gotman J; Frauscher B;

Stereo-electroencephalography (SEEG) is the gold standard to delineate surgical targets in focal drug-resistant epilepsy. SEEG uses electrodes placed directly into the brain to identify the seizure-onset zone (SOZ). However, its major constraint is limited brain coverage, potentially leading to m ...

Article GUID: 38897997