Keyword search (3,448 papers available)


Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors.

Author(s): Helfield BL, Yoo K, Liu J, Williams R, Sheeran PS, Goertz DE, Burns PN

Ultrasound Med Biol. 2020 Jul 27;: Authors: Helfield BL, Yoo K, Liu J, Williams R, Sheeran PS, Goertz DE, Burns PN

Article GUID: 32732167


Title:Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors.
Authors:Helfield BLYoo KLiu JWilliams RSheeran PSGoertz DEBurns PN
Link:https://www.ncbi.nlm.nih.gov/pubmed/32732167
DOI:10.1016/j.ultrasmedbio.2020.06.021
Category:Ultrasound Med Biol
PMID:32732167
Dept Affiliation: BIOLOGY
1 Department of Physics, Concordia University, Montreal, Canada; Department of Biology, Concordia University, Montreal, Canada. Electronic address: brandon.helfield@concordia.ca.
2 Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada.
3 Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada.

Description:

Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors.

Ultrasound Med Biol. 2020 Jul 27;:

Authors: Helfield BL, Yoo K, Liu J, Williams R, Sheeran PS, Goertz DE, Burns PN

Abstract

Submicron phase-change droplets are an emerging class of ultrasound contrast agent. Compared with microbubbles, their relatively small size and increased stability offer the potential to passively extravasate and accumulate in solid tumors through the enhanced permeability and retention effect. Under exposure to sufficiently powerful ultrasound, these droplets can convert into in situ gas microbubbles and thus be used as an extravascular-specific contrast agent. However, in vivo imaging methods to detect extravasated droplets have yet to be established. Here, we develop an ultrasound imaging pulse sequence within diagnostic safety limits to selectively detect droplet extravasation in tumors. Tumor-bearing mice were injected with submicron perfluorobutane droplets and interrogated with our imaging-vaporization-imaging sequence. By use of a pulse subtraction method, median droplet extravasation signal relative to the total signal within the tumor was estimated to be Etumor=37±5% compared with the kidney Ekidney=-2±8% (p < 0.001). This work contributes toward the advancement of volatile phase-shift droplets as a next-generation ultrasound agent for imaging and therapy.

PMID: 32732167 [PubMed - as supplied by publisher]