Reset filters

Search publications


By keyword
By department

No publications found.

 

Investigation of Macroscopic Mechanical Behavior of Magnetorheological Elastomers under Shear Deformation Using Microscale Representative Volume Element Approach

Author(s): Abdollahi I; Sedaghati R;

Magnetorheological elastomers (MREs) are a class of smart materials with rubber-like qualities, demonstrating revertible magnetic field-dependent viscoelastic properties, which makes them an ideal candidate for development of the next generation of adaptive ...

Article GUID: 38794567


Design Optimization of a Hybrid-Driven Soft Surgical Robot with Biomimetic Constraints

Author(s): Roshanfar M; Dargahi J; Hooshiar A;

The current study investigated the geometry optimization of a hybrid-driven (based on the combination of air pressure and tendon tension) soft robot for use in robot-assisted intra-bronchial intervention. Soft robots, made from compliant materials, have gai ...

Article GUID: 38275456


On the soft tissue ultrasound elastography using FEM based inversion approach

Author(s): Eshaghinia SS; Taghvaeipour A; Aghdam MM; Rivaz H;

Elastography is a medical imaging modality that enables visualization of tissue stiffness. It involves quasi-static or harmonic mechanical stimulation of the tissue to generate a displacement field which is used as input in an inversion algorithm to reconst ...

Article GUID: 38240143


The influence of inter-bubble spacing on the resonance response of ultrasound contrast agent microbubbles

Author(s): Yusefi H; Helfield B;

Ultrasound-driven microbubbles, typically between 1 and 8 µm in diameter, are resonant scatterers that are employed as diagnostic contrast agents and emerging as potentiators of targeted therapies. Microbubbles are administered in populations whereby their ...

Article GUID: 36223708


Optical Fiber Array Sensor for Force Estimation and Localization in TAVI Procedure: Design, Modeling, Analysis and Validation

Author(s): Bandari N; Dargahi J; Packirisamy M;

Transcatheter aortic valve implantation has shown superior clinical outcomes compared to open aortic valve replacement surgery. The loss of the natural sense of touch, inherited from its minimally invasive nature, could lead to misplacement of the valve in ...

Article GUID: 34450813


Finite Element Modelling of a Reflection Differential Split-D Eddy Current Probe Scanning Surface Notches.

Author(s): Mohseni E, França DR, Viens M, Xie WF, Xu B

J Nondestr Eval. 2020;39(2):29 Authors: Mohseni E, França DR, Viens M, Xie WF, Xu B

Article GUID: 32214578


Adaptive Neuro-fuzzy Inference System Trained for Sizing Semi-elliptical Notches Scanned by Eddy Currents.

Author(s): Mohseni E, Viens M, Xie WF

J Nondestr Eval. 2020;39(1):5 Authors: Mohseni E, Viens M, Xie WF

Article GUID: 31929668


Influence of Head Tissue Conductivity Uncertainties on EEG Dipole Reconstruction.

Author(s): Vorwerk J, Aydin Ü, Wolters CH, Butson CR

Front Neurosci. 2019;13:531 Authors: Vorwerk J, Aydin Ü, Wolters CH, Butson CR

Article GUID: 31231178


Zoomed MRI Guided by Combined EEG/MEG Source Analysis: A Multimodal Approach for Optimizing Presurgical Epilepsy Work-up and its Application in a Multi-focal Epilepsy Patient Case Study.

Author(s): Aydin Ü, Rampp S, Wollbrink A, Kugel H, Cho J-, Knösche TR, Grova C, Wellmer J, Wolters CH

Brain Topogr. 2017 Jul;30(4):417-433 Authors: Aydin Ü, Rampp S, Wollbrink A, Kugel H, Cho J-, Knösche TR, Grova C, Wellmer J, Wolters CH

Article GUID: 28510905


-   Page 1 / 1   -