| Keyword search (4,163 papers available) | ![]() |
"epilepsy" Keyword-tagged Publications:
| Title | Authors | PubMed ID | |
|---|---|---|---|
| 1 | Sleep magnetoencephalography enhances detection and source imaging of seizures and fast oscillations in focal cortical dysplasia | Heers M; Afnan J; Braun C; Grova C; Altenmüller DM; Steinhoff BJ; Dümpelmann M; Demerath T; Urbach H; Ethofer S; Siegel M; Schulze-Bonhage A; Lerche H; Li Hegner Y; | 41804684 PERFORM |
| 2 | SEC24C deficiency causes trafficking and glycosylation abnormalities in an epileptic encephalopathy with cataracts and dyserythropoeisis | Bögershausen N; Cavdarli B; Nagai T; Milev MP; Wolff A; Mehranfar M; Schmidt J; Choudhary D; Gutiérrez-Gutiérrez Ó; Cyganek L; Saint-Dic D; Zibat A; Köhrer K; Wollenweber TE; Wieczorek D; Altmüller J; Borodina T; Kaçar D; Haliloglu G; Li Y; Thiel C; Sacher M; Knapik EW; Yigit G; Wollnik B; | 40131364 BIOLOGY |
| 3 | Metrics for evaluation of automatic epileptogenic zone localization in intracranial electrophysiology | Hrtonova V; Nejedly P; Travnicek V; Cimbalnik J; Matouskova B; Pail M; Peter-Derex L; Grova C; Gotman J; Halamek J; Jurak P; Brazdil M; Klimes P; Frauscher B; | 39608298 SOH |
| 4 | EEG/MEG source imaging of deep brain activity within the maximum entropy on the mean framework: Simulations and validation in epilepsy | Afnan J; Cai Z; Lina JM; Abdallah C; Delaire E; Avigdor T; Ros V; Hedrich T; von Ellenrieder N; Kobayashi E; Frauscher B; Gotman J; Grova C; | 38994740 SOH |
| 5 | Systematic review of seizure-onset patterns in stereo-electroencephalography: Current state and future directions | Abdallah C; Mansilla D; Minato E; Grova C; Beniczky S; Frauscher B; | 38733701 PERFORM |
| 6 | How cerebral cortex protects itself from interictal spikes: The alpha/beta inhibition mechanism | Pellegrino G; Hedrich T; Sziklas V; Lina JM; Grova C; Kobayashi E; | 34002916 PERFORM |
| 7 | Fast oscillations >40 Hz localize the epileptogenic zone: An electrical source imaging study using high-density electroencephalography. | Avigdor T, Abdallah C, von Ellenrieder N, Hedrich T, Rubino A, Lo Russo G, Bernhardt B, Nobili L, Grova C, Frauscher B | 33450578 PERFORM |
| 8 | Large-scale mGluR5 network abnormalities linked to epilepsy duration in focal cortical dysplasia. | DuBois JM, Mathotaarachchi S, Rousset OG, Sziklas V, Sepulcre J, Guiot MC, Hall JA, Massarweh G, Soucy JP, Rosa-Neto P, Kobayashi E | 33401137 PERFORM |
| 9 | Source imaging of deep-brain activity using the regional spatiotemporal Kalman filter | Hamid L; Habboush N; Stern P; Japaridze N; Aydin Ü; Wolters CH; Claussen JC; Heute U; Stephani U; Galka A; Siniatchkin M; | 33250282 PERFORM |
| 10 | Effects of Independent Component Analysis on Magnetoencephalography Source Localization in Pre-surgical Frontal Lobe Epilepsy Patients | Pellegrino G, Xu M, Alkuwaiti A, Porras-Bettancourt M, Abbas G, Lina JM, Grova C, Kobayashi E, | 32582009 PERFORM |
| 11 | Detection of abnormal resting-state networks in individual patients suffering from focal epilepsy: an initial step toward individual connectivity assessment. | Dansereau CL, Bellec P, Lee K, Pittau F, Gotman J, Grova C | 25565949 PERFORM |
| 12 | Localization Accuracy of Distributed Inverse Solutions for Electric and Magnetic Source Imaging of Interictal Epileptic Discharges in Patients with Focal Epilepsy. | Heers M, Chowdhury RA, Hedrich T, Dubeau F, Hall JA, Lina JM, Grova C, Kobayashi E | 25609211 PERFORM |
| 13 | Detection and Magnetic Source Imaging of Fast Oscillations (40-160 Hz) Recorded with Magnetoencephalography in Focal Epilepsy Patients. | von Ellenrieder N, Pellegrino G, Hedrich T, Gotman J, Lina JM, Grova C, Kobayashi E | 26830767 PERFORM |
| 14 | Intracranial EEG potentials estimated from MEG sources: A new approach to correlate MEG and iEEG data in epilepsy. | Grova C, Aiguabella M, Zelmann R, Lina JM, Hall JA, Kobayashi E | 26931511 PERFORM |
| 15 | Source localization of the seizure onset zone from ictal EEG/MEG data. | Pellegrino G, Hedrich T, Chowdhury R, Hall JA, Lina JM, Dubeau F, Kobayashi E, Grova C | 27059157 PERFORM |
| 16 | Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy. | Chowdhury RA, Pellegrino G, Aydin Ü, Lina JM, Dubeau F, Kobayashi E, Grova C | 29164737 PERFORM |
| 17 | Disruption, emergence and lateralization of brain network hubs in mesial temporal lobe epilepsy. | Lee K, Khoo HM, Lina JM, Dubeau F, Gotman J, Grova C | 30094158 PERFORM |
| 18 | Metabotropic Glutamate Receptor Type 5 (mGluR5) Cortical Abnormalities in Focal Cortical Dysplasia Identified In Vivo With [11C]ABP688 Positron-Emission Tomography (PET) Imaging. | DuBois JM, Rousset OG, Guiot MC, Hall JA, Reader AJ, Soucy JP, Rosa-Neto P, Kobayashi E | 27578494 PERFORM |
| Title: | EEG/MEG source imaging of deep brain activity within the maximum entropy on the mean framework: Simulations and validation in epilepsy | ||||
| Authors: | Afnan J, Cai Z, Lina JM, Abdallah C, Delaire E, Avigdor T, Ros V, Hedrich T, von Ellenrieder N, Kobayashi E, Frauscher B, Gotman J, Grova C | ||||
| Link: | https://pubmed.ncbi.nlm.nih.gov/38994740/ | ||||
| DOI: | 10.1002/hbm.26720 | ||||
| Publication: | Human brain mapping | ||||
| Keywords: | HD-EEG; MEG; deep brain activity; epilepsy; source imaging; | ||||
| PMID: | 38994740 | Category: | Date Added: | 2024-07-12 | |
| Dept Affiliation: |
SOH
1 Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada. 2 Integrated Program in Neuroscience, McGill University, Montréal, Québec, Canada. 3 Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada. 4 Physnum Team, Centre De Recherches Mathématiques, Montréal, Québec, Canada. 5 Electrical Engineering Department, École De Technologie Supérieure, Montréal, Québec, Canada. 6 Center for Advanced Research in Sleep Medicine, Sacré-Coeur Hospital, Montréal, Québec, Canada. 7 Analytical Neurophysiology Lab, Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA. 8 Multimodal Functional Imaging Lab, Department of Physics and Concordia School of Health, Concordia University, Montréal, Québec, Canada. |
||||
Description: |
Electro/Magneto-EncephaloGraphy (EEG/MEG) source imaging (EMSI) of epileptic activity from deep generators is often challenging due to the higher sensitivity of EEG/MEG to superficial regions and to the spatial configuration of subcortical structures. We previously demonstrated the ability of the coherent Maximum Entropy on the Mean (cMEM) method to accurately localize the superficial cortical generators and their spatial extent. Here, we propose a depth-weighted adaptation of cMEM to localize deep generators more accurately. These methods were evaluated using realistic MEG/high-density EEG (HD-EEG) simulations of epileptic activity and actual MEG/HD-EEG recordings from patients with focal epilepsy. We incorporated depth-weighting within the MEM framework to compensate for its preference for superficial generators. We also included a mesh of both hippocampi, as an additional deep structure in the source model. We generated 5400 realistic simulations of interictal epileptic discharges for MEG and HD-EEG involving a wide range of spatial extents and signal-to-noise ratio (SNR) levels, before investigating EMSI on clinical HD-EEG in 16 patients and MEG in 14 patients. Clinical interictal epileptic discharges were marked by visual inspection. We applied three EMSI methods: cMEM, depth-weighted cMEM and depth-weighted minimum norm estimate (MNE). The ground truth was defined as the true simulated generator or as a drawn region based on clinical information available for patients. For deep sources, depth-weighted cMEM improved the localization when compared to cMEM and depth-weighted MNE, whereas depth-weighted cMEM did not deteriorate localization accuracy for superficial regions. For patients' data, we observed improvement in localization for deep sources, especially for the patients with mesial temporal epilepsy, for which cMEM failed to reconstruct the initial generator in the hippocampus. Depth weighting was more crucial for MEG (gradiometers) than for HD-EEG. Similar findings were found when considering depth weighting for the wavelet extension of MEM. In conclusion, depth-weighted cMEM improved the localization of deep sources without or with minimal deterioration of the localization of the superficial sources. This was demonstrated using extensive simulations with MEG and HD-EEG and clinical MEG and HD-EEG for epilepsy patients. |



