Keyword search (4,163 papers available)

"performance" Keyword-tagged Publications:

Title Authors PubMed ID
1 Hemodynamic performance and blood damage of the Intra-aortic pumps: A CFD-Based investigation Aycan O; Park Y; Kadem L; 41863715
ENCS
2 Achilles tendon ultrasound-derived properties of the dominant and non-dominant jumping leg of university basketball athletes: relation with performance, range of motion, and injury Soontjens O; Busner J; Fortin M; 41783785
SOH
3 The effect of 14 days Actovegin administration with or without high intensity training on exercise capacity and skeletal muscle mitochondrial respiration Hassø RK; Lindtofte S; Kosik B; Bergdahl A; Larsen S; 41553522
HKAP
4 Hierarchical Storage Management in User Space for Neuroimaging Applications Hayot-Sasson V; Glatard T; 41432812
ENCS
5 Functions of Informal Subgroups in Relation to Work Groups and Group Effectiveness Sidorenkov AV; Borokhovski EF; 40459704
CONCORDIA
6 An analysis of performance bottlenecks in MRI preprocessing Dugré M; Chatelain Y; Glatard T; 40072903
ENCS
7 The Effects of Weekly Levels of Supervisor Support and Workload on Next Week Levels of Well-Being, Satisfaction, and Performance as Mediated by Weekend Work Recovery Cheyroux P; Morin AJS; Colombat P; Blechman Y; Gillet N; 39676703
CONCORDIA
8 Exploring the glycoprotein washing fluid-assisted cleanup for the restoration of oil-contaminated shorelines with environmental integrity Sui J; Yue R; Bi H; Fu H; Yang A; Wang M; An C; 39260515
ENCS
9 A Survey on Error Exponents in Distributed Hypothesis Testing: Connections with Information Theory, Interpretations, and Applications Espinosa S; Silva JF; Céspedes S; 39056958
ENCS
10 Effects of color cues on eye-hand coordination training with a mirror drawing task in virtual environment Alrubaye Z; Hudhud Mughrabi M; Manav B; Batmaz AU; 38288362
ENCS
11 Development and validation of risk of CPS decline (RCD): a new prediction tool for worsening cognitive performance among home care clients in Canada Guthrie DM; Williams N; O' Rourke HM; Orange JB; Phillips N; Pichora-Fuller MK; Savundranayagam MY; Sutradhar R; 38041046
CRDH
12 Web-based processing of physiological noise in fMRI: addition of the PhysIO toolbox to CBRAIN Valevicius D; Beck N; Kasper L; Boroday S; Bayer J; Rioux P; Caron B; Adalat R; Evans AC; Khalili-Mahani N; 37841811
ENCS
13 Design optimization and experimental evaluation of a large capacity magnetorheological damper with annular and radial fluid gaps Abdalaziz M; Sedaghati R; Vatandoost H; 37521729
ENCS
14 Preparation, characteristics, and performance of the microemulsion system in the removal of oil from beach sand Bi H; Mulligan CN; Lee K; An C; Wen J; Yang X; Lyu L; Qu Z; 37399736
ENCS
15 Class imbalance should not throw you off balance: Choosing the right classifiers and performance metrics for brain decoding with imbalanced data Thölke P; Mantilla-Ramos YJ; Abdelhedi H; Maschke C; Dehgan A; Harel Y; Kemtur A; Mekki Berrada L; Sahraoui M; Young T; Bellemare Pépin A; El Khantour C; Landry M; Pascarella A; Hadid V; Combrisson E; O' Byrne J; Jerbi K; 37385392
IMAGING
16 The Role of Cohesion and Productivity Norms in Performance and Social Effectiveness of Work Groups and Informal Subgroups Sidorenkov AV; Borokhovski EF; 37232598
PSYCHOLOGY
17 Ice Hockey Goaltender Physiology Profile and Physical Testing: A Systematic Review and Meta-Analysis Marcotte-L' heureux V; Charron J; Panenic R; Comtois AS; 34567379
HKAP
18 On Left Ventricle Stroke Work Efficiency in Children with Moderate Aortic Valve Regurgitation or Moderate Aortic Valve Stenosis Asaadi M; Mawad W; Djebbari A; Keshavardz-Motamed Z; Dahdah N; Kadem L; 34357415
ENCS
19 Using 3D CityGML for the Modeling of the Food Waste and Wastewater Generation-A Case Study for the City of Montreal Braun R; Padsala R; Malmir T; Mohammadi S; Eicker U; 34240049
ENCS
20 Designing Ultrasmall Carbon Nanospheres with Tailored Sizes and Textural Properties for High-Rate High-Energy Supercapacitors Liu X; Vadiyar MM; Oh JK; Ye Z; 34229427
CHEMBIOCHEM
21 Analysis of biochar-mortar composite as a humidity control material to improve the building energy and hygrothermal performance. Park JH, Kim YU, Jeon J, Yun BY, Kang Y, Kim S 33611181
ENCS
22 Effects of Hemodynamic Conditions and Valve Sizing on Leaflet Bending Stress in Self-Expanding Transcatheter Aortic Valve: An In-vitro Study. Stanová V, Zenses AS, Thollon L, Kadem L, Barragan P, Rieu R, Pibarot P 31995230
ENCS
23 Experimental Investigation of Left Ventricular Flow Patterns After Percutaneous Edge-to-Edge Mitral Valve Repair. Jeyhani M, Shahriari S, Labrosse M 29168199
IMAGING
24 Performance monitoring in lung cancer patients pre- and post-chemotherapy using fine-grained electrophysiological measures Simó M; Gurtubay-Antolin A; Vaquero L; Bruna J; Rodríguez-Fornells A; 29387526
MLNP
25 Kinematics and muscle activation patterns during a maximal voluntary rate activity in healthy elderly and young adults. Chadnova E, St-Onge N, Courtemanche R, Kilgour RD 27909885
PERFORM

 

Title:Effects of Hemodynamic Conditions and Valve Sizing on Leaflet Bending Stress in Self-Expanding Transcatheter Aortic Valve: An In-vitro Study.
Authors:Stanová VZenses ASThollon LKadem LBarragan PRieu RPibarot P
Link:https://www.ncbi.nlm.nih.gov/pubmed/31995230?dopt=Abstract
DOI:10.1111/aor.13654
Publication:Artificial organs
Keywords:hemodynamic performanceleaflet bending stresspinwheeling indexsizingtranscatheter aortic valve implantation
PMID:31995230 Category:Artif Organs Date Added:2020-01-30
Dept Affiliation: ENCS
1 Aix Marseille Univ, IFSTTAR, LBA, Marseille, France.
2 Quebec Heart and Lung Institute, Laval University, Quebec, QC, Canada.
3 Department of Mechanical Industrial and Aerospace Engineering, Concordia University, Montreal, QC, Canada.
4 Cardiologie interventionnelle, Clinique des Fleurs, Ollioules, France.

Description:

Effects of Hemodynamic Conditions and Valve Sizing on Leaflet Bending Stress in Self-Expanding Transcatheter Aortic Valve: An In-vitro Study.

Artif Organs. 2020 Jan 29;:

Authors: Stanová V, Zenses AS, Thollon L, Kadem L, Barragan P, Rieu R, Pibarot P

Abstract

OBJECTIVES: Transcatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key. Increased leaflet mechanical stress is one of the main determinants of valve structural deterioration. This in vitro study aims at evaluating, leaflet bending stress (LBS) in the self-expanding TAV for different valve sizes, stroke volumes (SV) and degrees of valve oversizing (OS).

METHODS: Three different sizes (23, 26, 29 mm) of CoreValve (CV) were tested on a pulse duplicator in annulus size ranging from 17 to 26 mm. Leaflet bending stress and bending of the leaflet coaptation line in diastole (pin-wheeling index) were measured using high-speed camera imaging (1000 images/sec).

RESULTS: For each given CV and annulus size, geometric orifice area increased significantly with OS (p<0.001) and SV (p=0.001). LBS decreased with increasing prosthesis size and aortic annulus (AA) size while increasing with SV(p<0.03). The largest value of peak LBS (3.79 MPa) was obtained with the CV 23 mm in AA of 17 mm (%OS=35%), SV 90 ml and the smallest value (0.99 MPa) for the CV 29 mm in AA of 26 mm (%OS=12%), SV 30 ml. On multivariable analysis, LBS increased independently with larger OS, smaller AA size and higher SV. The pin-wheeling index increased with decreasing AA size and increasing OS.

CONCLUSIONS: Moderate valve OS, such as generally used for transcatheter aortic valve implantation, is associated with increased LBS during valve opening and closing, especially in small annuli. Hence, TAV OS may negatively impact long-term valve durability.

PMID: 31995230 [PubMed - as supplied by publisher]





BookR developed by Sriram Narayanan
for the Concordia University School of Health
Copyright © 2011-2026
Cookie settings
Concordia University