Effects of pool size and spacing on burning rate and flame height of two square heptane pool fires.

Author(s): Wan H, Gao Z, Ji J, Zhang Y, Li K, Wang L

J Hazard Mater. 2019 May 05;369:116-124 Authors: Wan H, Gao Z, Ji J, Zhang Y, Li K, Wang L

Article GUID: 30776594


Title:Effects of pool size and spacing on burning rate and flame height of two square heptane pool fires.
Authors:Wan HGao ZJi JZhang YLi KWang L
Link:https://www.ncbi.nlm.nih.gov/pubmed/30776594?dopt=Abstract
Category:J Hazard Mater
PMID:30776594
Dept Affiliation: ENCS
1 State Key Laboratory of Fire Science, University of Science and Technology of China, JinZhai Road 96, Hefei, Anhui 230026, China.
2 State Key Laboratory of Fire Science, University of Science and Technology of China, JinZhai Road 96, Hefei, Anhui 230026, China; Institute of Advanced Technology, University of Science and Technology of China, Hefei, Anhui 230088, China. Electronic address: jijie232@ustc.edu.cn.
3 Université Lille Nord de France, ENSCL, UMET/ISP R2Fire, Cité Scientifique-Bât C7-BP 90108, 59652 Villeneuve d'Ascq Cedex, France.
4 Department of Building, Civil and Environmental Engineering, Concordia University, 1445 de Maisonneuve Blvd. West, Montreal, QC H3G 1M8, Canada.

Description:

Effects of pool size and spacing on burning rate and flame height of two square heptane pool fires.

J Hazard Mater. 2019 May 05;369:116-124

Authors: Wan H, Gao Z, Ji J, Zhang Y, Li K, Wang L

Abstract

The interaction of multiple pool fires might lead to higher burning rate and flame height than single pool fire, raising the possibility of fire ignition and flame spread and increasing the risks to people, buildings and environment. To quantify the burning rate and flame height of multiple pool fires from the view of physical mechanism, this paper presents an experimental study on two identical square pool fires. Heptane was used as fuel. The pool size and spacing were varied. Results showed that both the burning rate and flame height change non-monotonically with spacing. From the view of air entrainment, a correlation for the flame height of two pool fires is developed involving pool size, spacing and the flame height of zero spacing. The comparison with experimental results shows that the developed correlation is suitable for two heptane or propane fires. A theoretical study based on energy balance at one of the pool surfaces is performed to evaluate the burning rate of two fires, which is finally expressed as a function of pool size, spacing, burning rate and the flame height of single fire. The proposed model is validated using the experimental and literature data, which presents a reasonable reliability.