Keyword search (3,171 papers available)


Automatic collateral circulation scoring in ischemic stroke using 4D CT angiography with low-rank and sparse matrix decomposition.

Author(s): Aktar M, Tampieri D, Rivaz H, Kersten-Oertel M, Xiao Y

Int J Comput Assist Radiol Surg. 2020 Jul 14;: Authors: Aktar M, Tampieri D, Rivaz H, Kersten-Oertel M, Xiao Y

Article GUID: 32662055

Two-stage ultrasound image segmentation using U-Net and test time augmentation.

Author(s): Amiri M; Brooks R; Behboodi B; Rivaz H;

PURPOSE: Detecting breast lesions using ultrasound imaging is an important application of computer-aided diagnosis systems. Several automatic methods have been proposed for breast lesion detection and segmentation; however, due to the ultrasound artefacts, ...

Article GUID: 32350786

MARIN: an open-source mobile augmented reality interactive neuronavigation system.

Author(s): Léger É; Reyes J; Drouin S; Popa T; Hall JA; Collins DL; Kersten-Oertel M;

PURPOSE: Neuronavigation systems making use of augmented reality (AR) have been the focus of much research in the last couple of decades. In recent years, there has been considerable interest in using mobile devices for AR in the operating room (OR). We pro...

Article GUID: 32323206

Cognitive load associations when utilizing auditory display within image-guided neurosurgery.

Author(s): Plazak J, DiGiovanni DA, Collins DL, Kersten-Oertel M

Int J Comput Assist Radiol Surg. 2019 Apr 17;: Authors: Plazak J, DiGiovanni DA, Collins DL, Kersten-Oertel M

Article GUID: 30997635

Deformable registration of preoperative MR, pre-resection ultrasound, and post-resection ultrasound images of neurosurgery.

Author(s): Rivaz H, Collins DL

Int J Comput Assist Radiol Surg. 2015 Jul;10(7):1017-28 Authors: Rivaz H, Collins DL

Article GUID: 25373447

Nonlinear deformation of tractography in ultrasound-guided low-grade gliomas resection.

Author(s): Xiao Y, Eikenes L, Reinertsen I, Rivaz H

Int J Comput Assist Radiol Surg. 2018 Mar;13(3):457-467 Authors: Xiao Y, Eikenes L, Reinertsen I, Rivaz H

Article GUID: 29299739

Correction to: Nonlinear deformation of tractography in ultrasound-guided low-grade gliomas resection.

Author(s): Xiao Y, Eikenes L, Reinertsen I, Rivaz H

Int J Comput Assist Radiol Surg. 2018 03;13(3):469 Authors: Xiao Y, Eikenes L, Reinertsen I, Rivaz H

Article GUID: 29392538

ARENA: Inter-modality affine registration using evolutionary strategy.

Author(s): Masoumi N, Xiao Y, Rivaz H

Int J Comput Assist Radiol Surg. 2019 Mar;14(3):441-450 Authors: Masoumi N, Xiao Y, Rivaz H

Article GUID: 30535826


Title:Cognitive load associations when utilizing auditory display within image-guided neurosurgery.
Authors:Plazak JDiGiovanni DACollins DLKersten-Oertel M
Link:https://www.ncbi.nlm.nih.gov/pubmed/30997635?dopt=Abstract
Category:Int J Comput Assist Radiol Surg
PMID:30997635
Dept Affiliation: ENCS
1 Gina Cody School of Engineering and Computer Science, Concordia University, EV 3.301, 1455 De Maisonneuve Blvd. W., Montreal, QC, H3G 1M8, Canada.
2 Montreal Neurological Institute, McGill University, Montreal, QC, Canada.
3 Gina Cody School of Engineering and Computer Science, Concordia University, EV 3.301, 1455 De Maisonneuve Blvd. W., Montreal, QC, H3G 1M8, Canada. marta@ap-lab.ca.

Description:

Cognitive load associations when utilizing auditory display within image-guided neurosurgery.

Int J Comput Assist Radiol Surg. 2019 Apr 17;:

Authors: Plazak J, DiGiovanni DA, Collins DL, Kersten-Oertel M

Abstract

PURPOSE: The combination of data visualization and auditory display (e.g., sonification) has been shown to increase accuracy, and reduce perceived difficulty, within 3D navigation tasks. While accuracy within such tasks can be measured in real time, subjective impressions about the difficulty of a task are more elusive to obtain. Prior work utilizing electrophysiology (EEG) has found robust support that cognitive load and working memory can be monitored in real time using EEG data.

METHODS: In this study, we replicated a 3D navigation task (within the context of image-guided surgery) while recording data pertaining to participants' cognitive load through the use of EEG relative alpha-band weighting data. Specifically, 13 subjects navigated a tracked surgical tool to randomly placed 3D virtual locations on a CT cerebral angiography volume while being aided by visual, aural, or both visual and aural feedback. During the study EEG data were captured from the participants, and after the study a NASA TLX questionnaire was filled out by the subjects. In addition to replicating an existing experimental design on auditory display within image-guided neurosurgery, our primary aim sought to determine whether EEG-based markers of cognitive load mirrored subjective ratings of task difficulty RESULTS : Similar to existing literature, our study found evidence consistent with the hypothesis that auditory display can increase the accuracy of navigating to a specified target. We also found significant differences in cognitive working load across different feedback modalities, but none of which supported the experiments hypotheses. Finally, we found mixed results regarding the relationship between real-time measurements of cognitive workload and a posteriori subjective impressions of task difficulty.

CONCLUSIONS: Although we did not find a significant correlation between the subjective and physiological measurements, differences in cognitive working load were found. As well, our study further supports the use of auditory display in image-guided surgery.

PMID: 30997635 [PubMed - as supplied by publisher]