Keyword search (4,163 papers available)

"Skinner CD" Authored Publications:

Title Authors PubMed ID
1 Luminescent Electro-Spun Nanofibers Crosslinked with Boronic Esters Exhibiting Controlled Release of Carbon Dots for Detection of Wound pHs and Enhanced Antimicrobial Lokuge ND; Casillas-Popova SN; Singh P; Clermont-Paquette A; Skinner CD; Findlay BL; Naccache R; Oh JK; 40920389
BIOLOGY
2 Multi-stimuli-responsive degradable boronic ester-crosslinked e-spun nanofiber wound dressings Casillas-Popova SN; Lokuge ND; Singh P; Cirillo A; Thinphang-Nga A; Skinner CD; Vuckovic D; Findlay BL; Oh JK; 40557709
BIOLOGY
3 pH-Responsive Degradable Electro-Spun Nanofibers Crosslinked via Boronic Ester Chemistry for Smart Wound Dressings Casillas-Popova SN; Lokuge ND; Andrade-Gagnon B; Chowdhury FR; Skinner CD; Findlay BL; Oh JK; 38989606
BIOLOGY
4 A threshold LC-MS/MS method for 92 analytes in oral fluid collected with the Quantisal® device Desharnais B; Lajoie MJ; Laquerre J; Mireault P; Skinner CD; 33035929
CHEMBIOCHEM
5 The Key Role of Intrinsic Lifetime Dynamics from Upconverting Nanosystems in Multiemission Particle Velocimetry Tessitore G; Maurizio SL; Sabri T; Skinner CD; Capobianco JA; 32924221
CNSR
6 Qualitative threshold method validation and uncertainty evaluation: A theoretical framework and application to a 40 analytes liquid chromatography-tandem mass spectrometry method Camirand Lemyre F; Desharnais B; Laquerre J; Morel MA; Côté C; Mireault P; Skinner CD; 32476284
CHEMBIOCHEM
7 Capillary electrochromatography of peptides and proteins. Bandilla D, Skinner CD 15354432
CHEMBIOCHEM
8 Design and optimization of porous polymer enzymatic digestors for proteomics. Lin W, Skinner CD 19575382
CHEMBIOCHEM
9 Increased oxidative modifications of amniotic fluid albumin in pregnancies associated with gestational diabetes mellitus. Boisvert MR, Koski KG, Skinner CD 20063865
CHEMBIOCHEM
10 A case of fatal idiosyncratic reaction to the designer drug 3,4-methylenedioxypyrovalerone (MDPV) and review of the literature. Desharnais B, Dazé Y, Huppertz LM, Mireault P, Skinner CD 28668987
CHEMBIOCHEM
11 A Tool for Automatic Correction of Endogenous Concentrations: Application to BHB Analysis by LC-MS-MS and GC-MS Desharnais B; Lajoie MJ; Laquerre J; Savard S; Mireault P; Skinner CD; 31141151
CHEMBIOCHEM

 

Title:Qualitative threshold method validation and uncertainty evaluation: A theoretical framework and application to a 40 analytes liquid chromatography-tandem mass spectrometry method
Authors:Camirand Lemyre FDesharnais BLaquerre JMorel MACôté CMireault PSkinner CD
Link:https://pubmed.ncbi.nlm.nih.gov/32476284/
DOI:10.1002/dta.2867
Publication:Drug testing and analysis
Keywords:method validationqualitativethresholduncertainty of measurement
PMID:32476284 Category:Drug Test Anal Date Added:2020-06-02
Dept Affiliation: CHEMBIOCHEM
1 Department of Mathematics, Université de Sherbrooke, 2500 Université Boulevard, Sherbrooke, Québec, J1K 2R1, Canada.
2 School of Mathematics and Statistics, The University of Melbourne, Parkville, Victoria, 3010, Australia.
3 Centre de recherche, Centre hospitalier universitaire de Sherbrooke, 12th Avenue North, Sherbrooke, Québec, J1H 5N4, Canada.
4 Department of Toxicology, Laboratoire de sciences judiciaires et de médecine légale, 1701 Parthenais Street, Montréal, Québec, H2K 3S7, Canada.
5 Department of Chemistry and Biochemistry, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada.
6 Department of Criminalistics, Laboratoire de sciences judiciaires et de médecine légale, 1701 Parthenais Street, Montréal, Québec, H2K 3S7, Canada.

Description:

Qualitative methods hold an important place in drug testing, filling central needs in screening and analyses, among others, linked to per se legislation. Nevertheless, the bioanalytical method validation guidelines do not discuss this type of method or describe method validation procedures ill-adapted to qualitative methods. The output of qualitative methods are typically categorical, binary results, such as presence/absence or above cut-off/below cut-off. As the goal of any method validation is to demonstrate fitness for use under production conditions, qualitative validation guidelines should evaluate performance based on discrete, binary results instead of the continuous measurements obtained from the instrument (e.g. area). A tentative validation guideline for threshold qualitative methods was developed by in silico modelling of measurements and derived binary results. This preliminary guideline was applied to a liquid chromatography-tandem mass spectrometry method for 40 analytes, each with a defined threshold concentration. Validation parameters calculated from the analysis of 30 samples spiked above and below the threshold concentration (false negative rate, false positive rate, selectivity rate, sensitivity rate and reliability rate) showed a surprisingly high failure rate. Overall, 13 out of the 40 analytes were not considered validated. A subsequent examination found that this was attributable to an appreciable shift in the standard deviation of the area ratio on a day-to-day basis, a previously undescribed and unaccounted-for behaviour in the qualitative threshold method validation literature. Consequently, the developed guideline was modified and used to validate a qualitative threshold method, based on the binary results for performance evaluation and incorporating measurement uncertainty.





BookR developed by Sriram Narayanan
for the Concordia University School of Health
Copyright © 2011-2026
Cookie settings
Concordia University