Keyword search (3,168 papers available)


Effects of Independent Component Analysis on Magnetoencephalography Source Localization in Pre-surgical Frontal Lobe Epilepsy Patients

Author(s): Pellegrino G, Xu M, Alkuwaiti A, Porras-Bettancourt M, Abbas G, Lina JM, Grova C, Kobayashi E,...

Objective: Magnetoencephalography source imaging (MSI) of interictal epileptiform discharges (IED) is a useful presurgical tool in the evaluation of drug-resistant frontal lobe epilepsy (FLE) patie...

Article GUID: 32582009

Accuracy and spatial properties of distributed magnetic source imaging techniques in the investigation of focal epilepsy patients.

Author(s): Pellegrino G, Hedrich T, Porras-Bettancourt M, Lina JM, Aydin Ü, Hall J, Grova C, Kobayashi E

Hum Brain Mapp. 2020 May 09;: Authors: Pellegrino G, Hedrich T, Porras-Bettancourt M, Lina JM, Aydin Ü, Hall J, Grova C, Kobayashi E

Article GUID: 32386115

Magnetoencephalography resting state connectivity patterns as indicatives of surgical outcome in epilepsy patients.

Author(s): Aydin Ü, Pellegrino G, Bin Ka'b Ali O, Abdallah C, Dubeau F, Lina JM, Kobayashi E, Grova C

J Neural Eng. 2020 Mar 18;: Authors: Aydin Ü, Pellegrino G, Bin Ka'b Ali O, Abdallah C, Dubeau F, Lina JM, Kobayashi E, Grova C

Article GUID: 32191632

Differences in MEG and EEG power-law scaling explained by a coupling between spatial coherence and frequency: a simulation study.

Author(s): Bénar CG, Grova C, Jirsa VK, Lina JM

J Comput Neurosci. 2019 Jul 11;: Authors: Bénar CG, Grova C, Jirsa VK, Lina JM

Article GUID: 31292816

Localization Accuracy of Distributed Inverse Solutions for Electric and Magnetic Source Imaging of Interictal Epileptic Discharges in Patients with Focal Epilepsy.

Author(s): Heers M, Chowdhury RA, Hedrich T, Dubeau F, Hall JA, Lina JM, Grova C, Kobayashi E

Brain Topogr. 2016 Jan;29(1):162-81 Authors: Heers M, Chowdhury RA, Hedrich T, Dubeau F, Hall JA, Lina JM, Grova C, Kobayashi E

Article GUID: 25609211

MEG-EEG Information Fusion and Electromagnetic Source Imaging: From Theory to Clinical Application in Epilepsy.

Author(s): Chowdhury RA, Zerouali Y, Hedrich T, Heers M, Kobayashi E, Lina JM, Grova C

Brain Topogr. 2015 Nov;28(6):785-812 Authors: Chowdhury RA, Zerouali Y, Hedrich T, Heers M, Kobayashi E, Lina JM, Grova C

Article GUID: 26016950

Detection and Magnetic Source Imaging of Fast Oscillations (40-160 Hz) Recorded with Magnetoencephalography in Focal Epilepsy Patients.

Author(s): von Ellenrieder N, Pellegrino G, Hedrich T, Gotman J, Lina JM, Grova C, Kobayashi E

Brain Topogr. 2016 Mar;29(2):218-31 Authors: von Ellenrieder N, Pellegrino G, Hedrich T, Gotman J, Lina JM, Grova C, Kobayashi E

Article GUID: 26830767

Intracranial EEG potentials estimated from MEG sources: A new approach to correlate MEG and iEEG data in epilepsy.

Author(s): Grova C, Aiguabella M, Zelmann R, Lina JM, Hall JA, Kobayashi E

Hum Brain Mapp. 2016 May;37(5):1661-83 Authors: Grova C, Aiguabella M, Zelmann R, Lina JM, Hall JA, Kobayashi E

Article GUID: 26931511

SPARK: Sparsity-based analysis of reliable k-hubness and overlapping network structure in brain functional connectivity.

Author(s): Lee K, Lina JM, Gotman J, Grova C

Neuroimage. 2016 07 01;134:434-449 Authors: Lee K, Lina JM, Gotman J, Grova C

Article GUID: 27046111

Source localization of the seizure onset zone from ictal EEG/MEG data.

Author(s): Pellegrino G, Hedrich T, Chowdhury R, Hall JA, Lina JM, Dubeau F, Kobayashi E, Grova C

Hum Brain Mapp. 2016 07;37(7):2528-46 Authors: Pellegrino G, Hedrich T, Chowdhury R, Hall JA, Lina JM, Dubeau F, Kobayashi E, Grova C

Article GUID: 27059157

Clinical yield of magnetoencephalography distributed source imaging in epilepsy: A comparison with equivalent current dipole method.

Author(s): Pellegrino G, Hedrich T, Chowdhury RA, Hall JA, Dubeau F, Lina JM, Kobayashi E, Grova C

Hum Brain Mapp. 2018 01;39(1):218-231 Authors: Pellegrino G, Hedrich T, Chowdhury RA, Hall JA, Dubeau F, Lina JM, Kobayashi E, Grova C

Article GUID: 29024165

Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy.

Author(s): Chowdhury RA, Pellegrino G, Aydin Ü, Lina JM, Dubeau F, Kobayashi E, Grova C

Hum Brain Mapp. 2018 02;39(2):880-901 Authors: Chowdhury RA, Pellegrino G, Aydin Ü, Lina JM, Dubeau F, Kobayashi E, Grova C

Article GUID: 29164737

Disruption, emergence and lateralization of brain network hubs in mesial temporal lobe epilepsy.

Author(s): Lee K, Khoo HM, Lina JM, Dubeau F, Gotman J, Grova C

Neuroimage Clin. 2018;20:71-84 Authors: Lee K, Khoo HM, Lina JM, Dubeau F, Gotman J, Grova C

Article GUID: 30094158

Optimal positioning of optodes on the scalp for personalized functional near-infrared spectroscopy investigations.

Author(s): Machado A, Cai Z, Pellegrino G, Marcotte O, Vincent T, Lina JM, Kobayashi E, Grova C

J Neurosci Methods. 2018 Nov 01;309:91-108 Authors: Machado A, Cai Z, Pellegrino G, Marcotte O, Vincent T, Lina JM, Kobayashi E, Grova C

Article GUID: 30107210

Complex patterns of spatially extended generators of epileptic activity: Comparison of source localization methods cMEM and 4-ExSo-MUSIC on high resolution EEG and MEG data.

Author(s): Chowdhury RA, Merlet I, Birot G, Kobayashi E, Nica A, Biraben A, Wendling F, Lina JM, Albera L, Grova C...

Complex patterns of spatially extended generators of epileptic activity: Comparison of source localization methods cMEM and 4-ExSo-MUSIC on high resolution EEG and MEG data.

Neuroimage. 2...

Article GUID: 27561712

Comparison of the spatial resolution of source imaging techniques in high-density EEG and MEG.

Author(s): Hedrich T, Pellegrino G, Kobayashi E, Lina JM, Grova C

Neuroimage. 2017 08 15;157:531-544 Authors: Hedrich T, Pellegrino G, Kobayashi E, Lina JM, Grova C

Article GUID: 28619655

Beyond spindles: interactions between sleep spindles and boundary frequencies during cued reactivation of motor memory representations.

Author(s): Laventure S, Pinsard B, Lungu O, Carrier J, Fogel S, Benali H, Lina JM, Boutin A, Doyon J

Sleep. 2018 Sep 01;41(9): Authors: Laventure S, Pinsard B, Lungu O, Carrier J, Fogel S, Benali H, Lina JM, Boutin A, Doyon J

Article GUID: 30137521


Title:Source localization of the seizure onset zone from ictal EEG/MEG data.
Authors:Pellegrino GHedrich TChowdhury RHall JALina JMDubeau FKobayashi EGrova C
Link:https://www.ncbi.nlm.nih.gov/pubmed/27059157?dopt=Abstract
Category:Hum Brain Mapp
PMID:27059157
Dept Affiliation: PERFORM
1 Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada.
2 Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada.
3 Département de Génie Electrique, École de Technologie Supérieure, Montreal, Québec, Canada.
4 Centre De Recherches En Mathématiques, Montreal, Québec, Canada.
5 Centre D'etudes Avancées En Médecine Du Sommeil, Centre De Recherche De L'hôpital Sacré-Coeur De Montréal, Montreal, Québec, Canada.
6 Physics Department and PERFORM Centre, Concordia University, Montreal, Québec, Canada.

Description:

Source localization of the seizure onset zone from ictal EEG/MEG data.

Hum Brain Mapp. 2016 07;37(7):2528-46

Authors: Pellegrino G, Hedrich T, Chowdhury R, Hall JA, Lina JM, Dubeau F, Kobayashi E, Grova C

Abstract

INTRODUCTION: Surgical treatment of drug-resistant epilepsy relies on the identification of the seizure onset zone (SOZ) and often requires intracranial EEG (iEEG). We have developed a new approach for non-invasive magnetic and electric source imaging of the SOZ (MSI-SOZ and ESI-SOZ) from ictal magnetoencephalography (MEG) and EEG recordings, using wavelet-based Maximum Entropy on the Mean (wMEM) method. We compared the performance of MSI-SOZ and ESI-SOZ with interictal spike source localization (MSI-spikes and ESI-spikes) and clinical localization of the SOZ (i.e., based on iEEG or lesion topography, denoted as clinical-SOZ).

METHODS: A total of 46 MEG or EEG seizures from 13 patients were analyzed. wMEM was applied around seizure onset, centered on the frequency band showing the strongest power change. Principal component analysis applied to spatiotemporal reconstructed wMEM sources (0.4-1 s around seizure onset) identified the main spatial pattern of ictal oscillations. Qualitative sublobar concordance and quantitative measures of distance and spatial overlaps were estimated to compare MSI/ESI-SOZ with MSI/ESI-Spikes and clinical-SOZ.

RESULTS: MSI/ESI-SOZ were concordant with clinical-SOZ in 81% of seizures (MSI 90%, ESI 64%). MSI-SOZ was more accurate and identified sources closer to the clinical-SOZ (P = 0.012) and to MSI-Spikes (P = 0.040) as compared with ESI-SOZ. MSI/ESI-SOZ and MSI/ESI-Spikes did not differ in terms of concordance and distance from the clinical-SOZ.

CONCLUSIONS: wMEM allows non-invasive localization of the SOZ from ictal MEG and EEG. MSI-SOZ performs better than ESI-SOZ. MSI/ESI-SOZ can provide important additional information to MSI/ESI-Spikes during presurgical evaluation. Hum Brain Mapp 37:2528-2546, 2016. © 2016 Wiley Periodicals, Inc.

PMID: 27059157 [PubMed - indexed for MEDLINE]